7
Burner cover/inner burner
ring/outer burner ring
Together with the inner burner ring the
outer burner ring forms a space where the
final mixture of gas and air takes place in
order to make the gas burn correctly.
Please note: It is consequently very
important that the inner burner ring/outer
burner ring is placed correctly, together
with the cover.
If the burner cover/rings are wrongly
placed the burner will operate incorrectly,
and the burner may be damaged within a
short space of time. It is also important,
that the inner air ring is placed correctly.
Ignition electrode (A)
The burner has been provided with an
ignition electrode. As long as the
operating knob is depressed, the
automatic ignition will ensure that a
spark is emitted between the ignition
electrode and the burner cover.
Thermo Sensor (B)
The gas unit features fully-secured gas
taps (thermo-fuse)
In case the flame goes out, the thermo
sensor automatically prevents gas
admission after a shorter time (Max. 90
seconds).
Note: Gas admission is always allowed
while the operation button is pressed -
See start-up procedure
Cover
Burner ring
Ignition electrode (A)
Thermo Sensor (B)
Burner Main nozzle
18
Model: WO3011AA20BE/A1
Type of gas
Adjusted for: Natural: G-20 - 20mbar
G-25 - 25mbar
Category and pressures
BE: II
2E+3+
20/25 - 28/37 mbar
Max. nominal load Q, H
S
:
Wok burner = 5,0 kW x 1
Total= 5,0 kW
Convertible to bottledgas: G30-28/37 mbar
FSD
The unit features fully-secured gas taps
(thermo-fuse).
H
S
= Gross calorific value
Q = Nominal load
Voltage= 220-240 V AC
Ignition transformer= 50 HZ - 0,6 VA
CE 048 AT- 0030
Radio-noise reduction
This unit observes the current EEC-directive
on radio noise reduction.
This gas appliance is -approved and
marked in accordance with the gas appliance
Directive (90/396/CEE), the low voltage
directive (73/23/CEE) and the EMC directive
(89/336/CEE incl. the agreed directive
changes.
Technical data
The Dropinett must be connected via
an external switch with a contact
gap of min. 3 mm (the main switch
may be used)
Cable type: 0,75 mm² HO5VV-F
N L1
230 V
1N + PE
Komentarze do niniejszej Instrukcji